FAA20 Embedded NEXCOM Vocoder
Board Manual
This manual has been prepared for the Federal Aviation Administration.
FA100-00107 (March 2004) Rev 1.0.0 Page 51
7.3.2 Acknowledgement Mode Upgrade
The FAA20 supports a virtual command (COM3) port over the nibble
interface (see Section 5.2.3). The acknowledgement mode configures the
FAA20 to print an acknowledgement message after each S-record is
successfully processed. This allows the host equipment to insure the
previous S-record has been successfully processed before transmitting the
next S-record. Note that the COM3 transmission rate is depending on the
nibble interface clock rate and frame size. For a typical setup (9600 Hz and
192 clocks/frame), the average byte transmission rate (not including flash
programming time) is 3000 char/sec.
To upgrade the FAA20 software using COM3, complete the following steps.
1. Send the PROG ACK command.
The FAA20 erases the main application flash memory to prepare
memory to be reprogrammed. The FAA20 prints an ERASING
FLASH message and then prints a READY message when this
process has been completed. The host software should wait for the
READY message before transmitting any S-record lines. Note also
that any other command traffic should be disabled before attempting
a software upgrade.
2. Send the first S-record line.
The FAA20 programs data associated with the record and then
prints an acknowledgement message, > ACK 0000. Always wait for
the FAA20 to acknowledge receipt of the current record before
transmitting the next record.
3. Send the next S-record line.
The FAA20 programs data associated with the line and then prints
an acknowledgement message, > ACK xxxx where xxxx is an
incrementing hex value for each record.
4. Repeat step #3 as necessary until all records are transmitted and
programmed.
The FAA20 continues to print ACK messages. After the last ACK
message, the FAA20 also prints a DONE message. The last record
(an S8 record) in the file indicates the end of the file and includes a
file checksum sequence.
5. Enter the RESET command to force the FAA20 to load the new
program.
After waiting 5 seconds for the power up sequence to complete, a
test command can be issued to the FAA20 to insure the unit has
rebooted.